• Notice: This site utilises 'cookies' for shopping and analytics, and by using it you agree to our Privacy Policy.
    This notice is designed to only be seen once on any particular device.

Glutathione (GSH) Directory Icon  - Kings Pathology Printer Icon - Kings Pathology

Haematology Overview / Directory

Test Icon  - Kings Pathology

Purpose of the test

Description: Deficiency of Glutathione is a very rare cause of haemolysis

Range Icon  - Kings Pathology

Reference Range

6.3 - 9.1 mmol/g Hb

notes Icon  - Kings Pathology

Sample Requirements

Minimum 1 ml EDTA blood. FBC and reticulocyte count must be performed and results sent with samples.

Transport Icon  - Kings Pathology

Storage and Transport

Samples can be sent first class post. Samples must be received in the laboratory within 3 days of collection. If there is a delay in sending store at 4°C and send a normal sample collected on the same day to act as a travel control.

Time Icon  - Kings Pathology

Turnaround Time

10 working days

Time Icon  - Kings Pathology

Time Limit for Extra Tests

Depends on tests required. Contact laboratory for further details.

Notes Icon  - Kings Pathology

Factors affecting results or interpretation

Recent blood transfusion.

Raised reticulocyte levels and/or raised WBC levels may affect assay.

Contact Icon  - Kings Pathology

Contacts

Tel 020 3299 9000 Laboratory Ext 2455 Office Ext 4337